Meter computer display screen image recognition acquisition data technology programme

As a professional provider of IoT data collection solutions, daq-iot, the data acquisition and IoT editor, will introduce the following content here and sincerely welcome everyone to discuss and communicate.

1 Identify the main programme as CDialRecService.exe

1.2 Support many types of digital meter recognition.

1.3 Support manual frame selection and automatic instrument area recognition + frame selection of two modes. Manual frame selection does not require training, recognition speed, but the instrument movement tolerance is poor, you must ensure that the relative position of the camera and the instrument remains unchanged. Automatic instrument area recognition + frame selection, need to collect sample images for annotation training, support for small movement of the instrument, recognition speed is slower.

1.4 Need to install VS running environment.

1.5 Support local directory / FTP / HTTP / CGI and other ways to get pictures, commonly used way for CGI.

1.6 CGI mode can be configured to automatically connect to the camera to capture pictures and store them in a specified directory.

1.7 After adjusting the identification parameters in the configuration interface, it will take effect without restarting the software.

1.8 Support modbus service and client-side data release.

1.9 Support RMQ/AMQ/MQTT to publish data.

1.10 Support mysql database records.

1.11 Provide local identification results query and timed export function.

2. Instructions for use

2.1 Software Installation

Green software does not need to be installed, copy to any location and double-click the main programme to run.

2.2 Software Description

1. Software catalogue

2.Software startup

The software starts as the above interface, you can switch to the application software parameters page for parameter setting.

Automatic restart: when manually exit the software, the software will be automatically restarted.

Running mode: when the configuration is completed, you can modify the service mode, configuration mode (if the software is being configured to not run the background recognition thread).

retention time: the retention time of the picture, more than will be deleted (while deleting the database records) restart time: you can set the software at what time to restart

Data cleansing: recognition results reported to the exception handling switch

Alarm pop-up window: recognition of abnormalities, the software pop-up window reminder

3. New recognition instrument

Switch to the data source configuration interface, according to the arrow direction of the flow of the operation

Input the data source name first->Click

Add data source->Select data source (local)->Select local file path (you can directly

(you can fill in the input box directly) -> click Save Parameters button to save the parameters.

4. Add recognition template

Switch to the identification template configuration interface, according to the following figure to identify the template configuration, enter the dial name -> click the

Add Meter

-> click the error reporting parameters button to save the parameters -> click the region identification button Select a picture in the pop-up dialogue box -> the software will automatically jump to the identification of the parameters of the region interface, configure the identification of the region -> click the identification of the test button (identification results will be displayed in the interface)

5. Recognition configuration

1) Select the region to identify the picture

  1. . The picture is displayed as follows, note that the first to open the regional box to select the switch (the left side of the instrument to be identified region, the right side of the region for the specific digital area)

3). Box to identify the region (left mouse button stand-alone point, the software will automatically connect the line, elected to take the fourth point, you can stand-alone right mouse button to close the constituency, in the middle if there is an error you can click on the previous step back to a point, or click on the clean up the constituency button, re-framing the region) when clicking on the Save Constituent Button, the software will automatically intercept out of the region (note that it will be used by the default parameters of the pre-processing (which can be switched to the pre-processing parameters interface to adjust the recognition again). preprocessing parameters interface to adjust the recognition again).

Digital mining IOT instrument identification software usage instructions document

4). Click on the left side of the saved area, the right side will display the selected area, if not used in accordance with the proportional scaling of the display, you can click on the refresh button, or click on the area identification button to re-identify once.

5) Follow the arrow instructions in order to operate, Note: Note that the boxed individual data as far as possible to include a complete digital region, otherwise it may not be accurate recognition, configuration is complete after the template can take effect.