1 Product Overview

  1. Product Introduction

DAQ-LP-UF4G low-power 4G/LoRaWANwireless communicationultrasonic flowmeterIt is a new generation non-contact flow measurement product independently developed byShanghai DAQ-IoTTechnology Co., Ltd. (brand: Shucai IoT). product adoptiontime difference methodThe principle of ultrasonic measurement consists of an ultrasonic flowmeter transmitter host, an externally clamped ultrasonic probe, a 4G battery powered acquisition module (model: DAQ-LP-GWRTU), and installation accessories. It can achieve accurate measurement of liquid flow inside the pipeline without damaging the pipeline or interrupting the fluid flow.

The product is equipped with a built-in 4G/LoRaWAN wireless communication module, which adopts a low-power design and battery power supply solution. It does not require external power supply and wiring, and is easy to install. It is particularly suitable for outdoor, temporary monitoring points, and application scenarios where wiring is difficult. Automatically upload device data toIoTcloud platformUsers can view Real-time traffic, accumulated water volume, and historical data curves anytime and anywhere through mobile apps or computer web pages, achieving remote, intelligent, and centralized management of traffic.

1.2 Model Description

The naming convention for this product model is as follows:

fieldmeaningExplanation
DAQData AcquisitionData Acquisition, Number of IoT product series prefixes
LPlow power consumptionLow Power, Battery powered low-power version
UFUltrasonic flow rateUltrasonic Flow, Ultrasonic flowmeter category
4G/LoRacommunication methodSupports remote data transmission via 4G cellular or Lorawan wireless networks

Table 1 Explanation of Model Naming Rules

Comparison of products in the same series: DAQ-GP-UF4G is the General Power version, suitable for installation scenarios with stable external power supply; DAQ-LP-UF4G is a low-power version powered by batteries, suitable for scenarios where there is no external power supply or wiring difficulties. The measurement principles and accuracy of the two are consistent, only the power supply method and power consumption management strategy are different.

1.3 Application Scenarios

This product is widely used in the following fields:

Flow monitoring of industrial circulating water and cooling water systems

Municipal water supply and drainage, tap water pipeline networkFlow measurement

HVAC chilled water and cooling water flow monitoring

distributed PV power station Cooling water/cleaning water flow monitoring

Flow monitoring of open channel pipelines for water conservancy and agricultural irrigation

Liquid flow measurement in industries such as chemical, pharmaceutical, food and beverage

Energy Management and Energy Monitoring System (EMS)

Temporary monitoring points, inspection and troubleshooting, and flow measurement in scenarios without power supply

2 Product Features

(1) Non contact external clamp measurement:ultrasonic probeExternally attached to the outer wall of the pipeline, without the need for pipe breakage or drilling, does not affect pipeline pressure and fluid quality, and installation and maintenance do not affect production operation.

(2) Low power battery supply:Adopting a low-power Hardware design and intelligent power management strategy, with a built-in large capacity lithium battery, the battery can last for 1-3 years under typical operating conditions without the need for frequent battery replacement.

(3)4GWireless remote transmission:built-in4G communication moduleSupports full network connectivity of China Mobile/China Unicom/China Telecom, with data automatically uploaded to the cloud without the need for communication cables, and can be installed and launched immediately.

(4) IoT Cloud platform:The supporting data acquisition IoT cloud platform supports centralized management of multiple devices, Real-time data monitoring, historical curve queries, and data report exports, meeting remote O&M needs.

(5) Multi terminal access:Supports multiple access methods such as mobile apps, WeChat mini programs, and computer web browsers, allowing users to view data anytime and anywhere without the need to install specialized software.

(6) Intelligent alarm push:Support multiple alarm conditions such as data overload, device offline, low battery, etc. The alarm information is pushed through the platform, SMS, or APP to timely grasp the abnormalities.

(7) Local LCD display:The host comes with an LCD display screen and operation buttons, allowing for on-site viewing of Real-time traffic, flow rate, cumulative volume, and signal quality, and supporting on-site parameter configuration.

(8) High protection level:The host and acquisition module are both designed with sealed enclosures, with a protection level ofIP65Adapt to harsh outdoor environments.

(9) Multiple installation methods:Supports various probe installation methods such as Z method, V method, N method, etc., suitable for a wide range of pipe diameters from DN15 to DN6000mm.

3 Technical parameters

3.1 Measurement of Performance Parameters

Parameter itemtechnical indicators
Measuring principleTime difference ultrasonic measurement
Applicable Pipe DiameterDN15~DN6000 mm (external clamp type)
Flow velocity range0~± 12 m/s (bidirectional measurement)
measurement accuracy± 1.0% (full tubeSteady-state flowUnder certain conditions)
repetitiveness±0.2%
linearity±0.5%
Applicable fluidsUniform single-phase liquids such as water, seawater, sewage, acid-base liquids, etc. (containing a small amount of bubbles or particles can also be measured)
fluid temperature-40 ℃~+160 ℃ (standard probe); High temperature probe can reach+200 ℃
Pipe materialSteel, cast iron, stainless steel, copper PVC、PE、 Dense homogeneous pipes such as fiberglass reinforced plastic
Installation methodZ method (large caliber), V method (small caliber), N method (small caliber)thick-walled pipe)
cumulative flowForward/reverse/net cumulative quantity, units can be selected from m ³, L, gal, etc
signal output4~20mA (optional)RS485 Modbus-RTUPulse output (optional)

Table 2 Measurement Performance Parameters

3.2 Electrical and Communication Parameters

Parameter itemtechnical indicators
Host power supplyDC 8~36V (powered by the acquisition module)
Power supply for acquisition moduleBuilt in large capacity lithium battery (3.6V/19Ah, replaceable)
low power modeSupport sleep/timed collection/timed upload, with an average working current of<50mA
battery lifeTypical operating conditions (collected/uploaded every 15 minutes) take about 1-3 years (depending on the settings and ambient temperature)
communication method4G LTE (China Mobile/China Unicom/China Telecom), backward compatible with GPRS
Communication ProtocolMQTT / TCP, Support data acquisition IoT cloud platform access
Local interfaceRS485(Modbus-RTU), Support docking with PLC/touch screen/DTU
data storageLocal circular storage, automatic transmission when disconnected from the network
sampling interval1 minute to 24 hours configurable
Upload interval1 minute to 24 hours configurable
antennaExternal 4Gsuction cup antenna(Standard 3-meter extension cable)

Table 3 Electrical and Communication Parameters

3.3 Environmental and Physical Parameters

Parameter itemtechnical indicators
Operating temperatureHost: -20 ℃~+60 ℃; Collection module: -20 ℃~+60 ℃; Probe: -40 ℃~+160 ℃
Storage temperature-40℃ ~ +80℃
Relative humidity≤ 95% RH (non condensing)
Protection ratingHost IP65; Acquisition module IP65; probeIP68
Explosion-proof gradeNon explosion proof (intrinsic safety)Explosion-proof typeOptional)
host sizeApproximately 200 x 140 x 70 mm (length x width x height)
Collection module sizeApproximately 120 × 90 × 55 mm (length × width × height)
Probe sizeApproximately 45 × 30 × 30 mm (per piece)
host weightAbout 0.8 kg
Weight of collection moduleAbout 0.3 kg (including battery)
Shell materialHost: Aluminum alloy spray coating; Collection module: ABS flame-retardant plastic; Probe: Aluminum alloy
Signal line lengthStandard 5-meter (customizable extension)

Table 4 Environmental and Physical Parameters

4 Product Composition and Structure

The standard configuration of DAQ-LP-UF4G low-power 4G ultrasonic flowmeter consists of the following parts, which work together to complete the taskflow measurementRemote transmission of data.

图片

Figure 1 Physical picture of DAQ-LP-UF4G product (host, acquisition module, probe and accessories)

4.1 Ultrasonic flowmeter host

The host is a blue aluminum alloy shell transmitter, equipped with an LCD display screen and 5 operation buttons (Menu button, up/down/left/right navigation button) on the front, and 5 M12 waterproof aviation connectors at the bottom for connecting probes, power supplies, and communication cables. The host is responsible for the transmission and reception of ultrasonic signals, time difference calculation, flow conversion, and local display.

The display screen can show key parameters such as instantaneous flow rate (m ³/h), flow velocity (m/s), positive cumulative amount (m ³), signal strength Q value, etc.

4.2 4G battery powered acquisition module

The model of the acquisition module is DAQ-LP-GWRTU, with a white ABS waterproof shell, built-in large capacity lithium battery and 4G communication module. Module throughRS485 interfaceCommunicate with the flowmeter host, collect flow data and upload it to the data acquisition IoT cloud platform via 4G network. The module shell label indicates the brand, model, communication method, production date, and manufacturer information, and is accompanied by a device QR code for platform binding.

The module hasLow power managementFunction: It can work at scheduled intervals according to the set collection and upload intervals, and enter sleep mode at other times to save power.

4.3 External clamp type ultrasonic probe

Standard configuration includes a pair of clamp type ultrasonic probes, labeled with "UP" (upstream/transmitter) and "DN" (downstream/receiver) respectively, with a blue aluminum alloy casing and a protection level of IP68. The probe is connected to the host through a dedicated signal line, and is attached to the outer wall of the pipeline with a coupling agent during installation. The flow velocity is calculated using the time difference of ultrasonic propagation in the fluid.

4.4 Signal lines and installation accessories

Standard configuration includes two dedicated signal lines with identification (upstream UP: red+black -); Downstream DN: red+black -), length 5 meters. Installation accessories include stainless steel clamps(hose clamp)、coupling agentCable ties, etc. are used to firmly fix the probe to the outer wall of the pipeline.

5 Installation Guide

5.1 Pre installation inspection

Please check the following before installation:

Confirm that the product model, accessories are complete, and the appearance is undamaged;

Confirm that the material, diameter, and wall thickness parameters of the tested pipeline are known;

Confirm that the fluid inside the pipeline is in a full state and is a uniform single-phase liquid;

Prepare installation tools: wrench, sandpaper, tape measure, marker pen, coupling agent, etc;

Confirm that the installation location has sufficient operating space and good 4G signal (can be tested using a mobile phone signal).

5.2 Selection of Installation Location

The correct selection of installation location is the key to ensuring measurement accuracy. Please follow the following principles:

chooseStraight pipe sectionThe length of the upstream straight pipe section shall not be less than 10 times the pipe diameter (10D), and the downstream shall not be less than 5 times the pipe diameter (5D);

Avoid flow disturbance components such as valves, elbows, tees, pumps, and reducers, and locate them at a sufficient distance downstream;

For horizontal pipelines, the probe should be installed on the side of the pipeline (3 o'clock or 9 o'clock direction), avoiding installation at the top (prone to gas accumulation) or bottom (prone to sedimentation);

RegardingVertical pipelineThe fluid should flow from bottom to top to ensure that the pipe is full;

The installation location should be easy to operate and maintain, avoiding high temperature, strong corrosion, and strong vibration areas;

The 4G acquisition module should be installed in a location with good signal quality, and the antenna should be placed outdoors or in a location with less metal obstruction as much as possible.

5.3 Probe installation method

Installation methodApplicable Pipe DiameterExplanation
V methodDN15 ~ DN300 mmThe most common method is to install two probes on the same side of the pipeline, and receive ultrasonic waves after reflection from the pipeline wall,ShengchengLonger, suitable for small and medium-sized thin-walled pipes.
Z methodDN300 ~ DN6000 mmTwo probes are installed on opposite sides of the pipeline, and ultrasonic waves directly penetrate the fluid with strong signals, suitable for large-diameter thick walled pipes.
N methodDN15~DN100 mm (thick wall)Two probes are installed on the same side, and ultrasonic waves are reflected twice by the pipe wall, which is suitable for small-diameter thick walled pipelines and improves signal quality.

Table 5 Selection of Probe Installation Methods

5.4 Installation steps

Step 1: Pipeline surface treatment: Use sandpaper to polish the installation position, remove paint, rust, and dirt until a metallic luster is exposed, ensuring a smooth surface.

Step 2: Apply coupling agent: Apply a layer of coupling agent evenly on the contact surface of the probe and the installation position of the pipeline, eliminate bubbles, and ensure good transmission of ultrasonic waves.

Step 3: Locate the probe: Mark the UP (upstream) and DN (downstream) probe positions with a tape measure and marker pen according to the installation distance (probe spacing) prompted in the host menu.

Step 4: Fix the probe: Attach the probe to the pipeline at the marked position, tighten the probe with a stainless steel clamp, and ensure that the probe is tightly attached to the pipe wall without looseness.

Step 5: Connect the signal line: Connect the UP probe cable to the host UP terminal, and connect the DN probe cable to the DN terminal, paying attention to the red positive and black negative polarity.

Step 6: Signal detection: Enter the host menu to check the signal strength Q value. The Q value should be between 60-100 and stable, otherwise the probe position needs to be adjusted or the coupling agent needs to be reapplied.

Step 7: Install the host and acquisition module: Fix the host and acquisition module on the wall or bracket, connect the RS485 communication line and power supply line, and fix the 4G antenna.

Step 8: Power on Test: Power on the acquisition module (insert battery or connect power), confirm that the host display is normal, the 4G indicator light of the acquisition module flashes, and the platform device is online.

6 Wiring Instructions

6.1 terminal blockdefinition

Terminal/InterfaceIdentifierFunctional Description
Probe interface 1UPUpstream probe connection port (transmitting end), red+black-
Probe interface 2DNDownstream probe connection port (receiving end), red+black-
power inputDC INDC power input, DC 8~36V (powered by the acquisition module)
RS485A / BRS485 communication interface, A positive and B negative, connected to the acquisition module
4G antennaANTExternal 4G suction cupAntenna interface
4~20mAOUTAnalog output (optional configuration)

Table 6 Definition of Wiring Terminals

6.2 System Wiring Diagram

The system wiring relationship is as follows: ultrasonic probe (UP/DN) → flowmeter host (probe interface) → RS485 communication line → 4G battery powered acquisition module (RS485 interface) → 4G network → data acquisition IoT cloud platform. The acquisition module also provides working power to the host.

Wiring precautions:

The polarity of the probe cable cannot be reversed, and UP and DN are not interchangeable;

RS485 communication line A should be connected to A, B should be connected to B, and cannot be reversed;

All joints should be tightened to ensure waterproof sealing;

Signal lines should be kept away from strong electrical cables to avoid interference;

4G antennas should be placed outdoors or in areas with good signal quality and cannot be shielded.

7 Operating Instructions

7.1 Key Functions

buttonIdentifierFunctional Description
Menu keyMenuEnter/exit menu, confirm selection
Up key▲Move the menu up and increase the value
Down arrow key▼The menu moves down and the values decrease
left button◀Move the cursor left to return to the previous level
right-click▶Move the cursor to the right to enter the next level/confirm

Table 7 Key Function Description

7.2 Display Interface

The host LCD display screen defaults to displaying the following information:

Display itemmeaningunit
trafficinstantaneous flow rateM ³/h (switchable between L/s, m ³/d, etc.)
flow velocityAverage fluid velocitym/s
Positive accumulationPositive cumulative trafficm³
Q =Signal strength/received signal quality0~100, the larger the value, the better the signal

Table 8 Display Screen Information Description

7.3 Basic parameter settings

After the first installation, the following pipeline parameters need to be set through the host menu to ensure accurate measurement:

Outer diameter (OD) of pipeline: Measure the circumference of the pipeline with a tape measure to calculate the outer diameter, or directly refer to the pipeline specifications;

Pipeline Wall Thickness (WT): Refer to pipeline specifications or usethickness gaugeMeasurement;

Pipeline material: Select the corresponding material (steel, cast iron, stainless steel, PVC, etc.);

Fluid type: Select the type of fluid being tested (water, seawater, sewage, etc.);

Installation method: choose V method, Z method or N method;

Probe installation distance: After setting, the host automatically calculates and displays the probe spacing, and installs the probe according to this distance;

Flow unit: Select instantaneous flow and cumulative flow units;

Accumulated amount reset: Perform forward/reverse accumulated amount reset operation in the menu.

8 IoT platform application

图片

8.1 Platform Overview

The data acquisition IoT cloud platform is a device access and development independently developed by Shanghai DAQ-IoT Network Technology Co., LtdData management platformProvide one-stop services such as data storage, display, analysis, and alarm for DAQ-LP-UF4G flow meters. The platform adopts B/S architecture, supports concurrent access of massive devices, ensures data security and reliability, and can be flexibly expanded.

8.2 Equipment Launch and Binding

The platform access parameters are pre-set before the device leaves the factory, and users only need to follow these steps to complete the device binding:

Log in to theIoTcloud platform website or mobile app, register an account, and log in;

Click on 'Add Device', scan the QR code on the collection module casing or manually enter the device SN number;

Fill in the device name, installation location, and other information to confirm the binding;

After the device is powered on, it automatically connects to the platform, and the status display "online" indicates successful online connection;

You can view the traffic data of Real-time on the device details page.

8.3 Real-time Data Monitoring

The platform supports multi terminal Real-time data viewing:

Computer web version: Log in to the platform's official website and view the traffic, flow rate, cumulative amount, signal strength, battery level, etc. of each device in "Real-time" or "Data Dashboard";

Mobile APP: Download the "Data Acquisition IoT" APP and log in to view device data anytime, anywhere on your phone;

WeChat Mini Program: Search for the "Data Collection IoT" mini program and quickly view it without downloading or installing it;

Data dashboard: supports custom large screen display, centralizing the display of key equipment data on the monitoring center large screen.

8.4 Historical data and curves

The platform automatically stores device historical data, and users can:

Query historical data by day, week, month, or custom time period;

Display the historical trend of instantaneous flow rate, flow velocity, cumulative quantity and other parameters in the form of a curve graph;

Support multi parameter screen comparison and multi device data overlay display;

The data can be exported in Excel/CSV format for report creation and Data Analytics.

8.5 Alarm Management

The platform supports multiple alarm condition settings and push notifications:

Alarm typetrigger conditionpush method
Traffic over limit alarmInstantaneous flow rate above/below the set thresholdPlatform messages, APP push notifications, SMS
Offline device alarmThe device has not uploaded data beyond the set timePlatform messages, APP push notifications, SMS
Low battery alarmThe battery level is below the set threshold (such as 20%)Platform messages, APP push notifications, SMS
Signal abnormality alarmThe Q value of ultrasonic signal intensity is lower than the set valuePlatform messages, APP push notifications

Table 9 Alarm Types and Push Methods

8.6 Centralized management of multiple devices

The platform supports hierarchical management of a large number of devices by project, region, and grouping, which can achieve:

Equipment grouping management, organizing equipment according to dimensions such as factory area, buildings, pipelines, etc;

Overview of equipment status, with a clear number of online/offline/alarm devices at a glance;

Batch parameter configuration and FOTA;

Multi level user permission management, supporting different roles such as administrators,O&Mpersonnel, visitors, etc;

Open API interface that can be integrated with third-party SCADA, EMS, smart water management and other systems.

9 Battery and Low Power Management

9.1 Battery specifications

The collection module has a built-in large capacityLithium thionyl chloride battery(ER34615,3.6V / 19Ah), It has the characteristics of low self discharge rate, wide operating temperature range, and high energy density, making it suitable for long-term low-power applications. The battery is designed to be replaceable, and users can replace it with a battery of the same specification by themselves.

9.2 Low power operating mode

The collection module adopts an intelligent low-power management strategy, and the workflow is as follows:

Timed wake-up: Wake up from sleep mode according to the set collection interval (default 15 minutes);

Data Acquisition: After waking up, read the flow rate, flow velocity, cumulative amount and other data of the flowmeter host through RS485;

Data upload: Upload data to the cloud platform through 4G network;

Entering sleep mode: Immediately enter low-power sleep mode after uploading is completed, waiting for the next wake-up.

9.3 Range estimation

Collection/upload intervalEstimated battery life (25 ℃)Applicable scenarios
1 minuteAbout 1-2 monthsHigh frequency monitoring, short-term projects
5 minutesAbout 4-6 monthsRoutine monitoring
15 minutes (default)About 1-2 yearsGeneral traffic monitoring, recommended settings
30 minutesAbout 1.5-2.5 yearsLow frequency monitoring
1 hourAbout 2-3 yearsLong term trend monitoring

Table 10 Estimated battery life (for reference only, actual battery life is affected by factors such as temperature and signal strength)

9.4 Electricity monitoring and replacement

The collection module Real-time monitors the battery voltage and uploads the power information to the platform. When the battery level drops below 20%, the platform triggers a low battery alarm to remind users to replace the battery in a timely manner. Steps for battery replacement:

Open the casing of the acquisition module (loosen the 4 fixing screws);

Remove the old battery and unplug the battery plug;

Insert the new battery plug, paying attention to the positive and negative poles;

Place the new battery into the battery compartment, cover the casing, and tighten the screws;

Confirm that the device is back online and the platform's battery level display has returned to normal.

Attention: Please recycle and dispose of used batteries according to local environmental regulations and do not dispose of them at will.

10 Maintenance and upkeep

10.1 Daily Inspection

Regularly check the online status and data of devices through the platform to ensure they are functioning properly;

Pay attention to the battery level and replace it promptly when the battery is low;

Check if the probe clamp is loose and if the signal line is damaged;

Check if the 4G antenna is intact and if the connection is secure.

10.2 Regular Maintenance

maintenance projectmaintenance cycleMaintenance content
Probe inspectionEvery 6 monthsCheck if the probe coupling agent has dried up and reapply if necessary; Check the tightness of the clamps
Signal quality inspectionEvery 6 monthsCheck the Q value of the host, adjust the probe position or replace the coupling agent when it is below 60
Battery replacementFollow the platform reminderReplace the battery when the battery level drops below 20%
Appearance cleaningEvery 12 monthsClean the host and collection module housing, check the waterproof seal
Wiring inspectionEvery 12 monthsCheck all joints for looseness, water ingress, and aging or damage of signal wires

Table 11 Regular Maintenance Schedule

10.3 Long term storage

When the device is not in use for a long time, please remove the battery and store the device in a dry, ventilated, and non corrosive gas environment with a storage temperature of -40 ℃~+80 ℃. When stored for more than 6 months, the battery level should be checked and charged or replaced.

11 Troubleshooting

Fault symptomPossible reasonsProcessing method
No display on the hostThe power supply is not connected; Battery depletion; Loose wiringCheck the battery and power supply line of the collection module; Replace the battery; Check the wiring
Low signal Q value or no signalImproper installation position of the probe; Coupling agent drying up; Loose probe; Pipe/parameter setting errorRe select the installation location; Apply coupling agent again; Tighten the clamp; Verify pipeline parameter settings
Traffic display is zero or abnormalThe pipeline is not full; Fluid does not flow; Reverse probe connection; Installation distance errorConfirm the full pipe status; Confirm fluid flow; Check the UP/DN wiring; Recalculate installation distance
Offline device platform4G signal is poor; Antenna not connected; Battery depletion; SIM card arrearsMove to the advantage of good signal; Check the antenna connection; Replace the battery; Check SIM card tariff
Data not updatedThe collection interval is set too long; The device is in sleep mode; communication failureCheck the collection/upload interval settings; Waiting for the next wake-up; Check 4G signal
Accumulated quantity inaccuratePipeline parameter setting error; There are non full tubes or bubbles present; Signal instabilityReset the outer diameter/wall thickness/material of the pipeline; Eliminate the influence of gases; Optimize probe installation
Short battery lifeThe collection/upload interval is too short; 4G signal difference leading to retransmission; low-temperature environmentExtend the collection and upload interval; Improve 4G signal; Pay attention to insulation in low temperature environments

Table 12 Common Troubleshooting Table

If the above methods still cannot solve the problem, please contact Shanghai DAQ-IoT Network Technology Co., Ltd. for technical support.

12 Precautions

12.1 Safety precautions

Please ensure personal safety during installation and maintenance, and wear safety belts when working at heights;

When installing on high-temperature pipelines, be careful to prevent burns and wear protective gloves;

This device is a non explosion proof product and is strictly prohibited from being used in flammable and explosive environments;

It is strictly prohibited to plug and unplug probes and communication lines while they are live to avoid damaging the equipment;

Please pay attention to the positive and negative poles when replacing the battery, and do not short-circuit the battery.

12.2 Precautions for Installation and Use

It is necessary to ensure that the tested pipeline is full, and the measurement is invalid in a non full pipeline state;

Strictly ensure the length of the upstream and downstream straight pipe sections, otherwise it will affect the measurement accuracy;

The surface of the pipeline where the probe is installed must be clean, flat, and free of rust;

The coupling agent must be evenly applied to eliminate bubbles, otherwise the signal attenuation will be severe;

Horizontal pipeline probes should be installed on the side, not on the top or bottom;

4G antennas should be installed outdoors or in locations with less metal obstruction as much as possible;

After the device is powered on for the first time, please wait for 3-5 minutes for it to complete network registration and platform connection;

Do not disassemble the host and acquisition module by yourself, otherwise the warranty will be lost.

13 Packaging List

serial numbernameModelquantityRemarks
1Ultrasonic flowmeter hostDAQ-LP-UF4G Host1 unitBlue aluminum alloy shell with LCD display
24G battery powered acquisition moduleDAQ-LP-GWRTU1 unitBuilt in lithium battery, including 4G communication
3External clip type ultrasonic probeStandard external clamp type1 pair (2 pieces)One UP/DN each, IP68
4Probe signal line5 meters2 piecesWith red and black markings, one UP/DN each
54G suction cup antenna3-meter extension cord1 piece
6RS485 communication cable2-core shielded wire1 pieceConnection between host and acquisition module
7Stainless steel hoopAdapt to pipe diameter2 setsFixed probe
8coupling agentUltrasonic coupling agent1 unit
9Instruction ManualThis manual1 copy
10Certificate of Conformity/1 copy
11Warranty card/1 copy

Table 13 Standard Packaging List

Note: The above are standard configurations, and specific configurations are subject to the actual purchase contract. Optional accessories include: high temperature probe, extended signal cable, 4-20mA output module, wall bracket, etc.

14 Warranty and Service

14.1 Warranty Terms

Shanghai DAQ-IoTTechnology Co., Ltd. provides a 12-month free warranty service for this product from the date of purchase. During the warranty period, our company is responsible for free repair or replacement of any malfunctions caused by quality issues with the product itself.

The following situations are not covered by the free warranty:

Damage caused by human error, improper installation or use;

Damage caused by unauthorized disassembly or modification;

Damage caused by force majeure (such as lightning strikes, flooding, fires, etc.);

Normal consumption of vulnerable parts and consumables (such as batteries, coupling agents, etc.);

Products that have exceeded the warranty period.

14.2 Technical Support

Our company provides lifelong technical support services. If users encounter any problems during product installation, use, or maintenance, they can contact the technical support team through the following methods.

评论